c) Pump-Out Timer (S4 dip switch 3 & 4)

During cycles when a pump out is called for, the pump motor drains the water tank for
the time determined by the pump-out timer (T1). The pump-out timer's harvest timer (T)
acts in place of the harvest timer (S4 dip switch 1 & ) during cycles with a pump out.
The pump-out timer is factory-adjusted, and no adjustment is required.

Dip Switch Setting

Time (seconds)

Harvest Water

Valve

No. 3

No. 4

T1

T

OFF

OFF

10

150

Closed

ON

OFF

10

180

Closed

OFF

ON

10

10

Open

ON

ON

0

180

Closed

T1: Time to drain the water tank
T: Harvest timer at pump out

Depending on the pump-out frequency control setting (dip switch 5 & 6), pump out
occurs every cycle, or every nd, 5th or 10th cycle.

d) Pump-Out Frequency Control (S4 dip switch 5 & 6)

The pump motor drains the water tank at the frequency set by the pump-out frequency
control.
The pump-out frequency control is factory-adjusted to drain the water tank every 10
cycles, and no adjustment is required. However, where water quality is bad and the
icemaker needs a pump out more often, the pump-out frequency can be adjusted as
shown in the table below.

Dip Switch Setting

Frequency

No. 5

No. 6

OFF

OFF

every cycle

ON

OFF

every  cycles

OFF

ON

every 5 cycles

ON

ON

every 10 cycles

e) Factory Use (S4 Dip Switch 7 & 8)

Factory set for optimum performance. Do not adjust.