15) Move the control switch to the "OFF" position.
16) Disconnect the float switch vent hose from the drain hose tee. Move the service switch

to the "DRAIN" position and the control switch to the "SERVICE" position.

17) From the tee on the drain hose, blow the drain water valve out using compressed air or

carbon dioxide.

18) Move the service switch to the "CIRC" position and the control switch to the "OFF"

position.

19) Reconnect the thermistor to the K3 connector on the control board. Reconnect the

water pump connector.

0) Close the inlet water supply line drain valve.
1) Remove all ice from the dispenser unit/storage bin and clean the dispenser unit/storage

bin liner using a neutral cleaner. Rinse thoroughly after cleaning.

) Turn off the power supply.
3) Replace all removed parts and panels in their correct positions.

Harvest Water Valve Hose

Harvest Water Valve

Wash Valve

Fill Water Valve

Drain Water Valve

Fill Water Valve Hose

Float Switch Vent Hose

Suction Hose

Drain Hose Tee

Fig. 5