B. condensing unit, Srk-14h – Hoshizaki KMS-1400MLH User Manual

Page 8

Advertising
background image

8

B. Condensing Unit

1. SRK-14H

Note: We reserve the right to make changes in specifications and design without prior

notice.

AC SUPPLY VOLTAGE

208-230/60/1 ( 3 wire with neutral for 115V )
( Connection to icemaker )

AMPERAGE

15 A ( 5 Min. Freeze AT 104°F / WT 80°F )

MINIMUM CIRCUIT AMPACITY

20 A

MAXIMUM FUSE SIZE

20 A

EXTERIOR DIMENSIONS ( WxDxH )

50" x 17" x 28" ( 1270 x 432 x 711 mm )

DIMENSIONS INCLUDING LEGS ( WxDxH ) 52-3/8" x 19-1/2" x 43" ( 1330 x 495 x 1092 mm )
EXTERIOR FINISH

Galvanized steel

WEIGHT

Net 230 lbs. ( 104 kg )

Shipping 273 lbs. ( 124 kg )

CONNECTIONS - ELECTRIC

Permanent - Connection

- REFRIGERANT

Suction line

1-1/8-12 UNF Fitting ( # 11 Parker )

Liquid line

1-1/16-12 UNF Fitting ( # 10 Parker )

COMPRESSOR

Hermetic, Model CS18K6E-PFV

CONDENSER

Air cooled, Fin and Tube type

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

FAN MOTOR PROTECTION

Thermal Protection

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

REFRIGERANT CONTROL

Condensing Pressure Regulator

REFRIGERANT CHARGE

15 lbs. 14 oz.

( 7200 g )

DESIGN PRESSURE

High 467 PSIG, Low 230 PSIG

OPERATING CONDITIONS

VOLTAGE RANGE

187 - 253 V

AMBIENT TEMP. ( Outdoor use )

-20 - 122° F

ACCESSORIES -SUPPLIED

Leg

2 pcs

Hex. Head Bolt w/Washer

M8 x 16

16 pcs

Hex. Nut

M8

16 pcs

ENG.F-032.1.0205