INSTALLATION

For best performance, mount the fixture about
6 feet (1.8 m) above the ground.

1. Remove

two nuts.

2. Remove

X-Bar.

Junction

Box

5. Attach X-Bar to

junction box

Due to the size and weight of the fixture, you
may find it helpful to have an assistant hold the
fixture in place while connecting the wires.

WIRING

One Motion Light

BLACK

WHITE

Two Motion

Lights

BLACK

WHITE

Twist the junction box wires and the

fixture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.

CAUTION: DO NOT connect the RED wire

unless you want to control other lights
from the motion sensor.

Black to black

White to white

MAX

MIN

3. Tighten screws

finger tight.

SENSITIVITY

4. Set sensitivity on fixture

back to the mid-position.

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and
twist one end together with the bare fixture wire
and the box ground wire. Secure with a wire
connector. Secure the other end of the "pigtail"
with the GND screw on the X-bar.

BLACK

WHITE

BLACK

WARNING: Turn power off at circuit

breaker.