4

598-1234-02

TESTING

Turn on the circuit breaker and light

switch.

The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.

Sensor

Motion

Least Sensitive

Most Sensitive

Note: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on, wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Avoid aiming the control at:

• Objects that change temperature rapidly,

such as heating vents and air condition-
ers.
These heat sources could cause false
triggering.

• Areas where pets or traffic may trigger

the control.

Nearby large, light-colored objects

reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.

30 ft.

(9.1 m)

Maximum Range

Maximum

Coverage Angle

6 ft.

(1.8 m)

150°

COMPLETE THE

INSTALLATION

Stuff the wires into the junction box. Make

sure none of the wires get pinched.

Slide the fixture onto the mounting

screws and tighten nuts.

Install one 100 W max. light bulb.

Install the lower glass assembly (if
applicable). Secure with decorative
screws.

After completing the tests, caulk between

fixture canopy and mounting surface
with silicone weather sealant.

Junction

Box

Switch the on-time to TEST position and

D

ual

B

rite

®

switch to the OFF position.

Motion

LOWER ARM INSTALLATION

(4294 Only)

Model 4294 comes with a separate lower
arm. Follow the directions below to attach
the lower arm.

1. Complete the in-

stallation steps
above.

2. Using the decora-

tive screws pro-
vided, secure the
lower arm to the
canopy and the
bottom of the low-
er glass assem-
bly as shown.

Canopy

Mounting

Surface

Advertising