Warning – Hearth and Home Technologies Heat & Glo CFL-18NG-C User Manual

Page 7

Advertising
background image

7

Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST-CFL-24-B • 526-910 Rev. E • 10/08

Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI

7. Test fi re the unit after referring to the SAFETY INFOR-

MATION and LIGHTING INSTRUCTIONS found in
Section 3 in this manual, or on the label plate assembly
found on the gas-burner.

8. After the gas line installation is complete, all connections

must be tightened and checked for leaks with a com-
mercially-available, non-corrosive leak check solution.
Be sure to rinse off all leak check solution following
testing. Refer to Section 3, OPERATING GUIDELINES
and MAINTENANCE INSTRUCTIONS.

9. Once the gas-burner is test fi red and gas supply lines

are purged, assemble the grate(s) and logs. Be certain
to follow the Log Placement Instructions shipped with
the unit. Remember to keep the Log Instructions along
with this manual for future use.

• This appliance may be used with a wall switch and/or

remote control.

• Use low resistance thermostat wire for wiring from igni-

tion system to the wall switch.

• Keep wire lengths as short as possible by removing any

excess wire length.

• Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:

• Installation and use of any damaged appliance

or vent system component.

• Modifi cation of the appliance.

• Installation other than as instructed by Hearth &

Home Technologies.

• Improper positionsing of the gas logs.

• Installation and/or use of any component part

not approved by Hearth & Home Technologies.

Any such action may cause a fi re hazard.

WARNING

BLACK

RED

BATTERY PACK

(BATTERIES REQUIRED)

WIRES
(TO BROWN)

ORANGE

GREEN

VALVE

GROUND TO

FIREPLACE

CHASSIS

WHITE

ORANGE

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

I

S

REMOTE OR

WALL SWITCH

Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

REMOTE
OR WALL
SWITCH

BLACK

BLACK

ON/OFF
SWITCH

RED

THERMOPILE

WHITE

Figure 4.

Advertising