Hearth and Home Technologies Heat & Glo CFL-18NG-C User Manual

Page 9

Advertising
background image

9

Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST-CFL-24-B • 526-910 Rev. E • 10/08

Upon completing the gas line connection, a small amount
of air will be in the lines. When fi rst lighting the pilot light,
it will take a few minutes for the lines to purge themselves
of this air. Once the purging is complete, the pilot and
burner will light and operate as indicated in the instruc-
tion manual. Subsequent lighting of the appliance will not
require such purging.

3

3

Operating Guidelines and Maintenance Instructions

Fire Risk
Be sure fi replace screen or glass doors are in
place when burning fi replace logs. Unless other
provisions for combustion air are provided, the
screen or doors shall have an opening for intro-
duction of combustion air. THIS GAS LOG SET
IS NOT DESIGNED TO OPERATE WITH AIR
TIGHT GLASS DOORS. Adequate combustion
and cooling air must be provided or the unit will
not function properly.

WARNING

Fire Risk
Explosion Risk
WARNING: To avoid possible injury, fi re and
explosion, please read and follow these pre-
cautions and all instructions on this appliance
before lighting the pilot. This appliance uses
L.P. (Propane) gas which is heavier than air and
will remain at fl oor level if there is a leak. Before
lighting, smell at fl oor level and/or use other
means (such as using a commercially-available,
non-corrosive leak check solution on all piping
and connections, using a gas detector, etc.) to
check for gas leaks. NOTE: L.P. (Propane) gas
can become odorless and CANNOT always be
detected by smell.

WARNING

B. Maintenance

Periodically remove the logs and examine the burner. If
dirty, clean with a soft brush. Also examine the area around
the burner air shutter and the pilot. Any dirt or lint in this
area should be removed. This will ensure long life and
trouble-free operation.

The appliance and venting system should be inspected
before initial use and inspected and cleaned at least an-
nually by a qualifi ed fi eld service person.

A. Before Lighting Appliance

Before lighting this appliance determine if it has a Standing
Pilot or Intellifi re ignition system by viewing the wiring
system and gas valve. If this appliance has a red or black
ignitor button (see Figure 3 and Figure 4) this appliance
has a Standing Pilot ignition system. If there is no red or
black ignitor button, this appliance has an Intellifi re ignition
system.

Before operating this appliance have a qualifi ed tech-
nician:

• Remove all shipping materials.

• Review proper placement of logs, rockwool, lava rock,

and vermiculite.

• Check the wiring.

• Ensure that there are no gas leaks.

WARNING

This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. Do
NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.

HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.

Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away

• CAREFULLY SUPERVISE children in same room as

fi replace.

• Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other fl ammable

materials away.

Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance.
For assistance or additional information consult a qualifi ed
installer, service agency or the gas supplier.

Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.

WARNING

WARNING

Advertising