Hoshizaki KM-630MWF User Manual

Page 20

Advertising
background image

20

DIP SWITCH NO.

1

2

3

4

5

6

7

8

9

10

KM-630MWF OFF OFF OFF OFF ON ON OFF OFF OFF OFF

KM-630MAF, OFF OFF OFF OFF ON ON OFF OFF ON OFF
KM-630MRF

[d] CONTROLS AND ADJUSTMENTS

The Dip Switch is factory-adjusted to the following positions:

Switch Nos. 1 and 2:

Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature

at the Evaporator outlet.

Switch Nos. 3 and 4:

Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker

resumes operation in 2 seconds. Then the Pump Motor drains the Water Tank
for the time determined by the Drain Timer. The Drain Timer also determines the
time to restrain completion of a defrost cycle, i.e. the minimum defrost time.

Switch Nos. 5 and 6:

Used for adjustment of the Drain Counter.
The Pump Motor drains the Water Tank at the frequency determined by the Drain

Counter.

Switch Nos. 7 and 8:
Used only for checking the Controller Board. Usually set in OFF position.

Switch Nos. 9 and 10:

Used for adjustment of Freeze Timer.
The Freeze Timer determines maximum
freeze cycle time. Upon termination of
Freeze Timer, machine initiates the
harvest cycle. After 2 consecutive timer
terminations, machine will shut down,
possibly indicating a problem.

Advertising
This manual is related to the following products: