Hoshizaki KM-630MWF User Manual

Page 36

Advertising
background image

36

PROBLEM

POSSIBLE CAUSE

REMEDY

l) Controller Board

1. Defective

1. See “II.2[e] CHECKING
CONTROLLER BOARD.”

m) Interlock Switch

1. “OFF” position.

1. Move to “ON” position.

(Cleaning Valve)

2. Bad contacts.

2. Check for continuity and
replace.

[2] Water

a) Float switch

1. Connector disconnected.

1. Place in position.

continues to

2. Leads opened or defective

2. Check and replace.

be supplied,

switch.

and the ice-

3. Float does not move freely.

3. Clean or replace.

maker will not

b) Controller Board

1. Defective.

1. Replace.

start.
[3] Compressor

a) Wash Switch

1. “WASH” position.

1. Move to “ICE” position.

2. Bad contacts.

2. Check and replace.

b) High Pressure

1. Dirty Air Filter or

1. Clean.

Controller

Condenser.
2. Ambient or condenser

2. Reduce ambient temp.

water temp. too warm.
3. Refrigerant overcharged.

3. Recharge.

4. Condenser water pressure

4. Check and get

too low or off. [Water-

recommended pressure.

cooled model only].
5. Fan not operating. [Except

5. See chart 1 - [6].

water-cooled model].
6. Refrigerant line or

6. Clean and replace Drier.

components plugged.

c) Water Regulator

1. Set too high.

1. Adjust lower.

d) Overload Protector

1. Bad contacts.

1. Check for continuity and
replace.

2. Voltage too low.

2. Increase voltage.

3. Refrigerant overcharged or

3. Recharge.

undercharged.
4. Line Valve continues to

4. Check Line Valve's

close in freeze cycle and

operation in freeze cycle

Overload Protector

and replace.

operates.

e) Starter

1. Bad contacts.

1. Check and replace.

2. Coil winding opened.

2. Replace.

f) Start Capacitor or

1. Defective.

1. Replace.

Run Capacitor
g) Magnetic Contactor

1. Bad contacts.

1. Check for continuity and
replace.

2. Coil winding opened.

2. Replace.

h) Compressor

1. Wiring to Compressor.

1. Check for loose
connection or open, and
replace.

2. Defective.

2. Replace.

3. Protector tripped.

3. Reduce temperature.

i) Controller board

1. Defective.

1. See “II.2. [e] CHECKING
CONTROLLER BOARD.”

[4] Water

a) Water Solenoid

1. Diaphragm does not close.

1. Check for water leaks

continues to

Valve

with icemaker off.

be supplied in

b) Controller Board

1. Defective.

1. See “II.2.[e] CHECKING

freeze cycle.

CONTROLLER BOARD.”

Advertising
This manual is related to the following products: