PROBLEM

POSSIBLE CAUSE

REMEDY

[5] No water

a) Water Supply Line

1. Water pressure too low and

1. Check and get

comes from

water level in Water Tank

recommended pressure.

Spray Tubes.

too low.

Water Pump

b) Water Solenoid

1. Dirty mesh filter or orifice

1. Clean.

will not start, or Valve

and water level in Water

freeze cycle

Tank too low.

time is too

c) Water System

1. Water leaks.

1. Check connections for

short.

water leaks, and replace.

2. Clogged.

2. Clean.

d) Pump Motor

1. Motor winding opened.

1. Replace.

2. Bearing worn out.

2. Replace.

3. Wiring to Pump Motor.

3. Check for loose
connection or open, and
replace.

4. Defective Capacitor.

4. Replace.

5. Defective or bound impeller. 5. Replace and clean.
6. Mechanical Seal worn out.

6. Check and replace.

e) Controller Board

1. Defective.

1. See “II.2. [e] CHECKING
CONTROLLER BOARD.”

[6] Fan Motor will

a) Fan Motor

1. Motor winding opened.

1. Replace.

not start, or is

2. Bearing worn out.

2. Replace.

not operating.

3. Wiring to Fan Motor.

3. Check for loose
connection or open, and

replace.

4. Defective Capacitor.

4. Replace

5. Fan blade bound.

5. Check and replace.

b) Controller Board

1. Defective.

1. See “II.2. [e] CHECKING
CONTROLLER BOARD.”

[7] All components a) Refrigerant

1. Undercharged.

1. Check for leaks and

run but no ice

recharge.

is produced.

2. Air or moisture trapped.

2. Replace Drier, and
recharge.

b) Compressor

1. Defective valve.

1. Replace.

c) Hot Gas Solenoid

1. Continues to open in freeze

1. Check and replace.

Valve

cycle.

d) Line Valve

1. Continues to close in

1. Check and replace

freeze cycle.

e) Water Supply Line

1. Condenser water pressure

1. Check and get

[Water-cooled model

too low or off and Pressure

recommended pressure.

only]

Control opens and closes

frequently.

Advertising