Top vent - horizontal termination, One elbow two elbows v – Heat & Glo Fireplace 2197-980 User Manual
Page 26
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13
26
Top Vent - Horizontal Termination
Figure 7.3
H
2
H
1
V
1
INSTALLED
HORIZONTALLY
Figure 7.4
One Elbow
Two Elbows
V
1
H
1
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not Allowed
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
5 ft.
1.52 m
3 ft.
914 mm
8 ft.
2.44 m
4 ft.
122 mm
11 ft.
3.35 m
5 ft.
152 mm
14 ft.
4.27 m
V
1
+ H
1
+ H
2
Maximum = 38 ft. (11.58 m)
H
1
+ H
2
Maximum = 14 ft. (4.27 m)
V
1
Minimum
H
1
Maximum
Elbow only
2 ft.
610 mm
1 ft.
305 mm
2-1/2 ft.
762 mm
2 ft.
610 mm
5-1/2 ft.
1.68 m
3 ft.
914 mm
9 ft.
2.74 m
4 ft.
1.22 m
12 ft.
3,66 m
5 ft.
1.52 m
15 ft.
4.57 m
V
1
+ H
1
Maximum = 38 ft. (11.58 m)
H
1
Maximum = 15 ft. (4.57 m)
Note: A 6 in. (152 mm) section of straight flue must be at-
tached to the fireplace before a 90° elbow.
Note: A 6 in. (152 mm) section of straight flue must be
attached to the fireplace before a 90° elbow.