Heat & Glo Fireplace 2197-980 User Manual

Page 29

Advertising
background image

29

Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13

Top Vent - Vertical Termination - (continued)

No Elbow

Figure 7.7

V

1

= 38 ft. Max. (11.58 m)

V

1

= 3 ft. Min. (914 mm)

VERTICAL TERMINATION BAFFLE

Note: The vertical termination baffle should be used for runs of 10 ft.

(3.05 m) or greater.
The vertical restrictor has a break away portion that creates a larger hole. If

venting 10-18 ft. (3.05 m - 5.49 m), the break away portion MUST be removed

and the larger hole must be used. If venting over 18 ft. (5.49 m), the break away

portion should be left in place and the small hole should be used.

BREAK AWAY PORTION

V

1