Electrical information, A. wiring requirements, B. intellifire plus – Heat & Glo Fireplace 2197-980 User Manual

Page 47: Ignition system wiring, C. optional accessories requirements, No fan option

Advertising
background image

47

Heat & Glo • SOHO-N-AUB • 2197-980 Rev. G • 2/13

12

Electrical Information

Figure 12.1 IPI Wiring Diagram /RC300AU

A. Wiring Requirements

NOTICE: This appliance must be installed by a qualified

electrician in accordance with the relevant national and

local regulations.
• Wire the appliance junction box to 220-240 VAC. This is

required for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire

220-240 VAC to the valve or to the appliance wall switch.

Incorrect wiring will damage controls.
NOTICE: The main supply to the appliance must have

isolation of a minimum 1/8 in. (3 mm) contact separation

in both poles.
WARNING! Risk of Injury! The gas supply shall be shut

off prior to disconnecting the electrical power and remov-

ing batteries (if installed) before proceeding with any

maintenance to the appliance.

GREEN

(MAIN)

ORANGE

(PILOT)

8K1 WIRE

HARNESS

GROUND

CONTROL MODULE

OPTIONAL ON/OFF

WALL SWITCH

RED

BLACK

BATTERY PACK

6V DC (C X 4)

BROWN

S

I

GROUND

TO CHASSIS

TO CORD ASSEMBLY

120VAC

WALL SWITCH

JUMPER WIRE

MODULE RESET

SWITCH

WIRE ASSEMBLY

OPTIONAL

JUNCTION CORD

WHITE

ORANGE

GAS TUBE

FLAME

SENSE

IGNITOR

B. IntelliFire Plus

TM

Ignition System Wiring

• Wire the appliance junction box to 220-240 VAC for

proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire

IPI controlled appliance junction box to a switched circuit.

Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus

TM

control valve which operates on a 6 volt/1.5 AMP system.

• Plug the 6 volt transformer plug into the appliance junction

box to supply power to the appliance OR install 4 C cell

batteries (not included) into the battery pack before use.

• An in-line isolation switch must be installed within 1

meter of the fireplace. This is required for servicing and/

or resetting the control module in the event of a control

module LOCK-OUT.

C. Optional Accessories Requirements

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved

accessories should be done now to avoid reconstruction.

Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-

liFire Plus

TM

wireless controls be used for their features

and functionality with the IntelliFire Plus

TM

ignition sys-

tem.

WARNING! Risk of Shock! Label all wires prior to dis-

connection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper

operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with

type 105 ºC (221 ºF) rated wire. Wire must have high tem-

perature insulation.

NO FAN OPTION