Depth offset, Temp offset, Speed calibration – Humminbird 531427-1_D User Manual

Page 92

Advertising
background image

85

Depth Offset

(Advanced)

Depth Offset will adjust the digital depth readout to indicate depth from the waterline or boat's
keel. Enter a positive vertical measurement from the transducer to the waterline to read the depth
from the waterline. Enter a negative vertical measurement from the transducer to keel to read the
depth from the keel. This menu choice is available only when in Advanced User Mode (see Setup
Menu Tab: User Mode
.)

To change the Depth Offset setting:

1. Make sure you are in Advanced User Mode, then highlight Depth Offset on the Setup menu.

2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset setting.

(-10.0 to +10.0 feet or -3 to 3 meters [International Models only], Default = 0)

Temp Offset

(Advanced)

Temp Offset will adjust the temperature readout by the amount entered. This menu choice is
available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)

To change the Temp Offset setting:

1. Make sure you are in Advanced User Mode, then highlight Temp Offset on the Setup

menu.

2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset setting.

(-10.0 to +10.0 degrees, Default = 0)

Speed Calibration

(Advanced, with Temp/Speed only)

Speed Calibration will adjust the speed readout by the percentage entered, and will appear in the
menu if a Temp/Speed Accessory is connected and the paddlewheel has moved at least once, when
the unit is in Advanced User Mode (see Setup Menu Tab: User Mode.)

To change the Speed Calibration setting:

1. Make sure you are in Advanced User Mode, then highlight Speed Calibration on the

Setup menu.

2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Speed Calibration

setting. (-20% to +20%, Default = 0%)

Advertising