Table 5-6 – HP TM 11-6625-2779-14&P User Manual

Page 46

Advertising
background image

Section V

Model 3555B

Table 5-6. Front Panel Trouble Analysis

3555B SHOULD INDICATE

SET ACTUALLY

CORRECTIVE

INPUT CONDITIONS

FUNCTION

(RANGE + METER)*

INDICATES

ACTION

FUNCTION: VF/Nm

DIAL BAT

In green area, BAT GOOD

Replace battery

1kHz, 0dBm, 600 BAL

Input: TMS, TERM
VF/Nm: 600 BAL

0dBm

±

0.2dBm

Refer to Paragraph 5-34

Change INPUT to BRDG
RANGE to +10dBm

+6dBm

±

0.2dBm

Refer to Paragraph 5-34

Depress 900 BAL

+4.2dBm ±0.2dBm

Refer to Paragraph 5-34

INPUT to TERM
RANGE to 0dBm

-0.1 5dBm

±

0.2dBm

Refer to Paragraph 5-34

FILTERS

INPUT: NOISE TERM

0dBm

Refer to Paragraph 5-37

NOISE WTG: 3kHz FLAT
VF/Nm, 600 BAL

0dBm ±0.2dBm

Refer to Paragraph 5-37

Change to C MSG

0dBm +±0.2dBm

Refer to Paragraph 5-37

Change to 15kHz FLAT

0dBrn

±

0.2dBm

Refer to Paragraph 5-37

Change to PROG

0dBm

±

1dBm

Refer to Paragraph 5-37

FUNCTION: CARRIER

20kHz, 0dBm

INPUT: TMS, TERM

600 BAL

FUNCTION: CARRIER

0dBm

Refer to Paragraph 5-34

600 BAL

Change INPUT to BRDG
RANGE to +10dBm

+6dBm

±

0.5dBm

Refer to Paragraph 5-34

Depress 135 BAL
RANGE to +20dBm

+12.6dBm

±

0.5dBm

Refer to Paragraph 5-34

Change INPUT to TERM
RANGE to 0dBm

-2.2dBm

±

0.5dBm

Refer to Paragraph 5-34

Change to 75

UNBAL INPUT: TMS, TERM
FUNCTION: 75 UNBAL

0dBm

±

0.2dBm

Refer to Paragraph 5-34

RANGE: 0dBm

Change INPUT to BRDG
RANGE to 10dBm

±

6dBm +0.2dBm

Refer to Table 5-8

Change INPUT back to

TERM

RANGE to 0dBm

0dBm

±

0.2dBm

Refer to Table 5-8

RANGE

1kHz, 600 BAL,
LEVEL +10dBm

Change RANGE to +10dBm
FUNCTION: VF/Nm 600 BAL

+10dBm

±

0.2dBm

See Paragraph 5-35

LEVEL -10dBm

Change RANGE to -10dBm

-10dBm ±0.2dBm

See Paragraph 5-35

LEVEL -20dBm

Change RANGE to -20dBm

-20dBm

±

0.2dBm

See Paragraph 5-35

5-12