Table 5-9, Table 5-10, Table 5-11 – HP TM 11-6625-2779-14&P User Manual

Page 50

Advertising
background image

Section V

Model 3555B

Table 5-9. Range Attenuation and Amplifier Gain

Attenuator Pads Used

Amplifier Gain

(See Figure 7-3)

Switching

RANGES

1

2

3

4

+30

X

X

X

+20

X

X

X

+10

X

X

0

X

X

-10

X

X

-20

X

-30

X

-40

X

-50
-60

A2R13, A2R14

-70

A2R13

-80

Ranges Affected +30 -20

+30

+20

-60 and -70

If Defective

+20 thru

0

-10

+10 +30

-30

-40

Table 5-11. Factory Selected Values

Designator

Purpose

C4

Adjust balance at 600kHz, 135 BAL

A1C5

Padding capacitor for A1 C4

A1C9

Adjust balance 20kHz, 600 BAL (VF/Nm)

A1C8

Padding capacitor for A1C7

A1C10 and

Frequency response correction for A1TI

A1R12

A1R14

600 BAL, VF/Nm calibration

A3C1

Padding capacitor for A2C12

A3C15

Frequency response, 20Hz, -80dBm, 600
BAL (VF/Nm)

A3R46

Adjust the bias level for A3Q10 (-10V at +
side of A3C24)

A3R72

Response, 20Hz, 600 BAL (VF/Nm)
-70dBm and 20Hz, 900 BAL, 0dBm.
Compromise between these two settings.

A3R74and

Meter tracking at 1/3 full scale. Resistors

A3R75

should be the same value.

Table 5-10. Resistance Checks

RANGE (dBm)

Pin 1 to 3

Pin 2 to 3

Pin 1 to 2

-50 thru +30

154 kilohms

0

Infinity

-60

13 kilohms

28.64 kilohms

41.6 kilohms

-70

2.33 kilohms

28.64 kilohms

31 kilohms

-80

0

28.64 kilohms

28.64 kilohms

5-16