23

Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06

1.4

IGNITION SYSTEM WIRING

This gas heater is equipped with an electronic igni-
tion system which operates on a 6 volt system.

This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before use.

Figure 31. Electronic Ignition Wiring Diagram

Shock Risk
• Replace damaged wire with type 105°C

rated wire.

• Wire must have high temperature insulation.

WARNING

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and danger-
ous operation. Verify proper operation after servicing.

CAUTION

IGNITION
MODULE

(6V)

ON/OFF

WALL SWITCH

VALVE

FLAME SPARKER/

SENSOR

ANT.

REMOTE

CONTROL

HOT

NEUTRAL

GROUND

BATTERY PORT

VALVE

PILOT

IGNITION MODULE

6VDC

ON/OFF
SWITCH

THERMOCOUPLE

BLOCK

(CONNECTED TO
BACK OF VALVE)

GAS LINE
CONNECTED TO
BACK OF VALVE

PLUG IN