24

Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06

Figure 32.

NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED
WITH TYPE 105

C RATED WIRE.

Figure 33.

BROWN

BROWN

BLUE

BLACK

BLUE

BLACK

(HOT) BROWN

(NEUTRAL) BLUE

BLACK

BL

A

C

K

BLUE

BROWN

GREEN/YELLOW

BLOWER

TEMPERATURE

SENSOR SWITCH

240VAC JUNCTION BOX

VARIABLE

SPEED

CONTROL

BROWN

BLUE

BLACK

BROWN

BLUE

BR

O

W

N

BL

U

E

BLACK

GREEN/YELLOW
STRIPE

GR

E

E

N

/Y

E

L

L

OW

ST

R

IPE

1.5 BLOWER FAN

These heaters have a factory installed Fan, Elec-
trical Junction Box, Variable Speed Rheostat
Control Switch and Temperature Sensor Switch
for the fan. These components are located be-
hind the lower door.

Use of the fan requires that the Junction Box
(factory installed) be connected to 240 VAC
service before permanently enclosing the heater.
The access hole for connecting the service wires
is found on the right exterior side of the unit.
See Figure 33 for wire connection detail.