5-1. TROUBLE SHOOTING GUIDE

Problem Cause Correction


POWER switch ON but fryer

• Open circuit

• Plug fryer in

completely inoperative

• Check breaker or fuse at supply

box

Shortening will not

• Open high limit

• Reset high limit per

heat but lights are on.

circuit

High Limit Temperature

Error message “E10”

Control Section

• Drain valve open

• Turn drain valve handle to

Error message “E15”

closed position



Foaming or boiling

• Water in shortening

• At end of Cook Cycle, drain

over of shortening

shortening and clean

• Improper or bad

• Use recommended shortening

shortening


• Improper filtering

• Refer to the procedure covering

filtering the shortening


• Improper rinsing after

• Clean and rinse the frypot, then

cleaning the fryer

dry thoroughly


Shortening will not

• Drain valve clogged

• Open valve, force cleaning

drain from frypot

with crumbs

brush through drain


Filter switch on,

• Motor thermal

• Reset thermal switch per section

motor does not run

protector tripped

on Filter Pump Motor

Protector – Manual Reset