Model OFE/OFG/OEA/OGA-341, 342



5-2. ERROR CODES

In the event of a control system failure, the digital

display will show an "Error Message." These

messages are coded: “E4”, “E5”, “E6”, “E10”,

“E15”, “E20”, “E-31”, “E41”, “E46”, “E54”,

E-70-A & B and “E92”. A constant tone is heard

when an error code is displayed, and to silence this

tone, press any button.


DISPLAY

CAUSE PANEL

BOARD

CORRECTION


“E-4”

Control board

Turn switch to OFF position, then turn switch back to ON.

overheating

if display shows “E-4”, the control board is getting too hot;

check the louvers on each side of the unit for obstructions


“E-5”

Shortening

Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-5”, the heating circuits and temperature

probe should be checked


“E-6 A”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe open

if display shows “E-6”, check the temperature probe;

to replace, refer to Technical Manual


“E-6 B”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe shorted

if display shows “E-6” check the temperature probe;

to replace, refer to Technical Manual

“E-10”

High limit

Reset the high limit by manually pushing up on the reset

button; if high limit does not reset, high limit must be

replaced;

refer

to

Technical

Manual

“E-15”

Drain switch

Close drain, using the drain valve handle; if display still

failure

shows “E-15”, check the drain microswitch; refer to

Technical

Manual

“E-41”,

Programming

Turn switch to OFF, then back to ON; if display shows any

“E-46”

failure

of the error codes, try to reinitialize the control (Special

Program Section) if error code persists, replace the control

board; refer to Technical Manual





5-2