Model OFE/OFG/OEA/OGA-341, 342



5-2. ERROR CODES
(Continued)


DISPLAY

CAUSE

PANEL BOARD CORRECTION


“E-20 A” Vacuum

Press the timer button to try the ignition process again;

switch failure

if “E-20 A” persists check vacuum switch; refer to

(stuck closed)

Technical Manual

“E-20 B”

Draft fan or

Press the timer button to try the ignition process again;

vacuum

if “E-20 B” persists, check vacuum switch or the blower

switch failure

motor; refer to Technical Manual

(stuck open)

“E-20 C” Ignition modules

Press the timer button to try the ignition process again; if

not responding “E-20 C” persists, check the ignition

module, the spark ignitor, or the I/O board; refer to

Technical

Manual


“E-20 D”

Pilots not lit or

Press the timer button to try the ignition process again; if

no flame sense

“E-20 D” persists, check the ignition module, the I/O

board, or the flame sensor; refer to Technical Manual


“E-31”

Elements up-

Lower elements into frypot

Electric

units

only


Fan switch jumper

Check for jumper wire on 12-pin connector & add if missing

wire

missing


“E-54”

PCB component

Turn switch to OFF position, then turn switch back to ON;

failure

if “E-54” persists, have PCB replaced


“E-70A”

Fan switch jumper

Have jumper wire checked on 12 pin connect to panel

missing


“E-70B”

MV jumper missing

Have jumper wire checked on connectors to panel


“E-92”

24 VAC fuse

24 VAC fuse on I/O board open; check for shorted

on I/O open

component in 24-volt circuit (i.e.., hi limit, drain switch,

air

switch)



908