Honeywell PERFECT WINDOW HR200 User Manual

Page 25

Advertising
background image

APPENDICES

HR150 and HR200 Ventilation performance.

Fig. 22.

M29743B

25

50

75

100

125

150

175

.1

.2

.3

.4

.5

.6

.7

83

77

73

67

58

47

18

177

164

156

143

123

100

38

EXT STATIC

PRESSURE

(Pa)

(in. wg)

(L/s)

(cfm)

NET SUPPLY

AIR FLOW

HR150 VENTILATION PERFORMANCE (HV1)

20

40

60

80

100

120

140

160

180

200

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

STATIC PRESSURE (IN W.G.)

AI

R

F

LO

W

(C

FM

)

MANUFACTURER’S DATA

1

1

HIGH SPEED

LOW SPEED

M29744B

.1

.2

.3

.4

.5

.6

.7

101

97

91

87

80

73

65

214

206

193

184

170

155

137

EXT STATIC

PRESSURE

(Pa)

(in. wg)

(L/s)

(cfm)

NET SUPPLY

AIR FLOW

HR200 VENTILATION PERFORMANCE (HVI)

25

50

75

100

125

150

175

20

40

60

80

100

120

140

160

180

200

220

240

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

STATIC PRESSURE (IN W.G.)

AI

R

F

LO

W

(C

FM

)

MANUFACTURER’S DATA

1

HIGH SPEED

LOW SPEED 1

STALE

AIR FROM

INSIDE

DEFROST

PORT

FRESH

AIR TO

INSIDE

FRESH AIR

FROM OUTSIDE

STALE

AIR TO

OUTSIDE

M29741A

DEFROST

DAMPER

CONDENSATE

DRAINS

BALANCING

DAMPER

BLOWERS

FILTERS

14-3/4

(375)

19

(483)

FRONT CLEARANCE OF 25 INCHES (635 MM)

IS RECOMMENDED FOR SERVICING UNIT.

ALL DUCT

CONNECTIONS

6 (150)

MOUNTING

SCREWS

1

1

BALANCING

DAMPER

33-5/8

(850)

HR150 and HR200 dimensions in in. (mm).

Fig. 23.

HR150, 200; ER150, 200 Perfect Window™ Fresh Air Ventilation Systems 68-0171—12

23

Advertising