12 i – hussmann P/N 0420057_B User Manual

Page 18

Advertising
background image

6. NOTE:

R

ECEPTACLE HARNESS WIRING MUST HAVE

INSULATION SLEEVE INSTALLED PRIOR TO ROUTING

.

Leaving about 12 inches of harness hang out of
case, route receptacle harness wiring from the

3

/

4

-in. bushing, down the LH upright wireway

through hole and into case wireway.
NOTE: C

OMMUNICATION CABLE WIRING CAN BE

ROUTED SIMILARLY

.

7. Install the rear door center trim with

3

/

4

-in.

bushing by routing wire harness through

3

/

4

-in.

bushing and attach with #8 truss head screws.

8. Reposition top over rear door center trim and
attach using #8 truss head screws.

9. Reposition scale stand and attach using #8
truss head screws.

10. Install scale stand upright cover with #8
blunt tip sheet metal screws.

11. Connect wiring to power in wireway.

12. Restore power. Check for proper operation.

Some stores specify an isolated ground for scale
stand convenience outlets. If required, apply the
following:

• Isolated ground sticker to scale stand.
• Isolated ground tag to ground wire in case

wireway.

1-12

I

NSTALLATION

P/N 0420057_B

U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • WWW.HUSSMANN.COM

Case
Wireway

Receptacle
Harness

Route Communication
Cable to Junction Box
as shown. Coil excess
cable in Junction Box.

Mount Junction Box at this
location when scale stand
is mounted at Center Mullion.

Communication Cable

Advertising