7.1.2 Fitting the insert tool

4

CAUTION
Wear protective gloves when changing the insert tool.

1.

Disconnect the supply cord plug from the power
outlet.

2.

Check that the connection end of the insert tool
is clean and lightly greased. Clean it and grease
it if necessary.

3.

Check that the sealing lip of the dust shield
is clean and in good condition. Clean the dust
shield if necessary or replace it if the sealing lip
is found to be damaged (please refer to the “Care
and maintenance” section).

4.

Push the insert tool into the chuck and rotate it
while applying slight pressure until it engages in
the guide grooves.

5.

Push the insert tool further into the chuck until it
is heard to engage.

6.

Check that the insert tool has engaged correctly
by pulling it.

7.1.3 Removing the insert tool

5

CAUTION
Wear protective gloves when changing insert tools as
the insert tool will get hot during use.

1.

Disconnect the supply cord plug from the power
outlet.

2.

Open the chuck by pulling back the chuck release
sleeve.

3.

Pull the insert tool out of the chuck.

7.1.4 Removing the chuck

6

CAUTION
Remove the depth gauge from the side handle and
the insert tool from the chuck in order to avoid injury.

NOTE
Set the selector switch to the “Chiseling” position
before removing the chuck.

1.

Disconnect the supply cord plug from the power
outlet.

2.

Pull the chuck sleeve forward and hold it se-
curely.

3.

Remove the chuck by pulling it away from the
power tool.

7.1.5 Fitting the chuck

7

CAUTION
Remove the depth gauge from the side handle and
the insert tool from the chuck in order to avoid injury.

NOTE
Set the selector switch to the “Chiseling” position
before removing the chuck.

1.

Disconnect the supply cord plug from the power
outlet.

2.

Grip the chuck sleeve, pull it forward and hold it
securely in this position.

3.

Slide the chuck onto the guide tube from the
front and then release the sleeve.

4.

Rotate the chuck until it is heard to engage.

7.2 Operation

CAUTION
Working on the material may cause it to splinter.
Wear eye protection and protective gloves. Wear
breathing protection if no dust removal system is
used.
Splintering material presents a risk of injury to
the eyes and body.

CAUTION
The work generates noise. Wear ear protectors.
Exposure to noise can cause hearing loss.

7.2.1 Working at low temperatures

NOTE
The hammering mechanism works only when the
power tool has reached a minimum operating tem-
perature.

Bring the drill bit briefly into contact with the base
material while allowing the power tool to run under
no load until the minimum operating temperature is
reached. If necessary, repeat this procedure until the
hammering mechanism begins to operate.