Husky A05051 User Manual

Page 11

Advertising
background image

11- ENG

A05051

Extension Cords

If an extension cord must be used, be
sure it is:

a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product

in good condition

no longer than 50 feet

16 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 14, 12, 10, and 8
AWG may also be used.

Voltage and Circuit Protection

Refer to the specification chart for the
voltage and minimum branch circuit
requirements.

Risk of Unsafe
Operation. Certain

air compressors can be operated
on a 15 amp circuit if the following

conditions are met.

1.

Voltage supply to circuit must
comply with the National
Electrical Code.

2.

Circuit is not used to supply any
other electrical needs.

3.

Extension cords comply with
specifications.

4.

Circuit is equipped with a 15
amp circuit breaker or 15 amp
time delay fuse. NOTE: If
compressor is connected to a
circuit protected by fuses, use
only time delay fuses. Time delay
fuses should be marked "D" in
Canada and "T" in the US.

If any of the above conditions cannot
be met, or if operation of the
compressor repeatedly causes
interruption of the power, it may be
necessary to operate it from a 20
amp circuit. It is not necessary to
change the cord set.

Advertising