Husky A05051 User Manual

Page 19

Advertising
background image

19- ENG

A05051

PROBLEM

CAUSE

CORRECTION

Compressor is
not supplying
enough air to
operate
accessories.

Prolonged excessive use of
air.

Compressor is not large
enough for air requirement.

Hole in hose.

Air leaks.

Decrease amount of air
usage.

Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.

Check and replace if
required.

Tighten any exposed fittings.

Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse or
circuit breaker with higher
rating than that specified for
your particular branch circuit.

Check for proper fuse. You
should use a time delay fuse.

Check for low voltage
problem.

Check the extension cord.

Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.

Have checked by a Trained
Service Technician.

Fuse blown, circuit breaker
tripped.

Extension cord is wrong
length or gauge.

Loose electrical
connections.

Faulty motor.

Check the extension cord.

Check wiring connection
inside terminal box.

Motor will not
run.

Advertising