Honeywell CHRONOTHERM T8621A User Manual

Page 12

Advertising
background image

12

T8621A,C,D

INSTALLATION

Fig. 11—T8621D 2-stage heat/2-stage cool thermostat with HEAT-OFF-COOL system and AUTO-ON fan
switching; auto fan on heat and cool; convertible to auto fan on cool only.

FOR ELECTRIC HEAT APPLICATIONS (AUTO FAN OPERATES WITH W1
AND Y1). USE ONLY ONE TRANSFORMER; JUMPER R AND RC. SET
SWITCH TO ELECTRIC POSITION.

NOMINAL 24 VAC POWER MUST BE PRESENT BETWEEN R AND C FOR
THERMOSTAT OPERATION.

DENOTES THERMOSTAT TO SUBBASE INTERCONNECTION.

M1016C

HEATING
TRANSFORMER

R

C

W1

W2

B

STAGE 1
HEAT RELAY

STAGE 2
HEAT RELAY

HEATING DAMPER OR
CHANGEOVER RELAY

COOLING
TRANSFORMER

O

Y2

Y1

G

RC

STAGE 1
COOLING RELAY

STAGE 2
COOLING RELAY

COOLING DAMPER OR
CHANGEOVER RELAY

FAN RELAY

HEAT 2

HEAT 1

HIGH
LIMIT

HIGH
LIMIT

L1
(HOT)

L2

HEAT

OFF

COOL

SYSTEM
SWITCH

COOL 1

COOL 2

AUTO

ON

FAN
SWITCH

L1
(HOT)

L2

NON-ELECTRIC

ELECTRIC

FAN
OPERATION
SWITCH

3

2

4

1

3

1

SUBBASE
LOGIC/
CONTROL
CIRCUIT

5

1

2

3

4

5

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

FOR GAS OR OIL APPLICATIONS OR ELECTRIC HEAT APPLICATIONS
WHERE THE FAN OPERATION IS CONTROLLED INDEPENDENTLY OF
THE THERMOSTAT (AUTO FAN OPERATES WITH Y1 ONLY), TWO
TRANSFORMERS MAY BE USED. SET SWITCH TO NON-ELECTRIC
POSITION.

POWER
SUPPLY

THERMOSTAT
LOGIC CIRCUIT