17

68-0058—1

T8621A,C,D

INSTALLATION • CHECKOUT

Fig. 17—Mounting thermostat on subbase.

M 843

PM

MORNIMG

MON

HEAT ON

ROOM

SYSTEM

AUTO

PM

MORNIMG

MON

HEAT ON

ROOM

SYSTEM

RUN

PROGRAM

TIME

TEMPERATURE

PRESENT

SETTING

SKIP

NEXT

PERIOD

CHANGE
TO LAST

PERIOD

SET

PRESENT
DAY/TIME

HOLD
TEMP

DAY

SET

HEAT/COOL

CANCEL
PERIOD

COPY
FROM

AHEAD

WARMER

COPY

TO

BACK

COOLER

PERIOD

A.

B.

C.

HEAT A

UTO C

OOL OF

F

ON AUT

O

FAN

HEATING

Move the system switch to HEAT and the fan switch to

AUTO. Press WARMER key until the setting is about 10

°

F [6

°

C] above room temperature. Heating should start

(both stages if multistage), and the fan should run (may be
a short delay on forced air systems). Press cooler key until
the setting is about 10

°

F [6

°

C] below room temperature.

The heating equipment should shut off, followed by the
fan.

NOTE: On an AUTO changeover thermostat, the cooling

temperature must be set at least 3

°

F [2

°

C] above the

heating temperature, or display will flash.

COOLING

CAUTION

Do not operate cooling if outdoor temperature is
below 50

°

F [10

°

C]. Refer to manufacturer’s

recommendations.

NOTE: When cooling setting is changed, thermostat will

wait up to five minutes before turning on the cooling
equipment. This delay is to protect the compressor.

Move the system switch to COOL and the fan

switch to AUTO. Press COOLER key until the setting
is about 10

°

F [6

°

C] Below room temperature. The

cooling equipment and fan should start (both stages if
multistage). Press WARMER key until the setting is
about 10

°

F [6

°

C] above room temperature. The

cooling equipment and fan should stop.

NOTE: On an AUTO changeover thermostat, the heating

temperature must be set at least 3

°

F [2

°

C] below the

cooling temperature, or display will flash.

FAN

Move the system switch to OFF, and the fan switch to

ON. The fan should run continuously. When the fan switch
is in the AUTO position, fan operates directly with the
thermostat call for cooling and also with the thermostat
call for heating.

Checkout

!