Unit Numbers


OmniPro II systems have 511 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10
module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:


OmniPro II Unit Numbers

Module / Output Unit Numbers

1 - 16

HLC Room 1 and 2, UPB Unit ID 1-16, CentraLite loads 1-16, RadioRA Lighting Zones or
Master Controls 1-16, and X-10 modules 1 – 16 (House Code X)

17 - 32

HLC Room 3 and 4, UPB Unit ID 17-32, CentraLite loads 17-32, RadioRA Lighting Zones
and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1)

(1 - 31)

ALC addresses 1-31, Module 1 - Branch 1 *

33 - 48

HLC Room 5 and 6, UPB Unit ID 33-48, CentraLite loads 33-48, RadioRA Lighting Zones
and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2)

49 - 64

HLC Room 7 and 8, UPB Unit ID 49-64, CentraLite loads 49-64, RadioRA Lighting Zones
and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3)

(33 - 63)

ALC addresses 1-31, Module 1 - Branch 2 *

65 - 80

HLC Room 9 and 10, UPB Unit ID 65-80, CentraLite loads 65-80, or X-10 modules
1 – 16 (House Code X+4)

81 - 96

HLC Room 11 and 12, UPB Unit ID 81-96, CentraLite loads 81-96, or X-10 modules
1 – 16 (House Code X+5)

(65 - 95)

ALC addresses 1-31, Module 1 - Branch 3 *

97 - 112

HLC Room 13 and 14, UPB Unit ID 97-112, CentraLite loads 97-112, or X-10 modules
1 – 16 (House Code X+6)

113 - 128

HLC Room 15 and 16, UPB Unit ID 113-128, CentraLite loads 113-128, or X-10 modules
1 – 16 (House Code X+7)

(97 - 127)

ALC addresses 1-31, Module 1 - Branch 4 *

129 - 144

HLC Room 17 and 18, UPB Unit ID 129-144, CentraLite loads 129-144, or X-10 modules
1 – 16 (House Code X+8)

145 - 160

HLC Room 19 and 20, UPB Unit ID 145-160, CentraLite loads 145-160, or X-10 modules
1 – 16 (House Code X+9)

(129 - 159)

ALC addresses 1-31, Module 2 - Branch 1 *

161 - 176

HLC Room 21 and 22, UPB Unit ID 161-176, CentraLite loads 161-176, or X-10 modules
1 – 16 (House Code X+10)

177 - 192

HLC Room 23 and 24, UPB Unit ID 177-192, CentraLite loads 177-192, or X-10 modules
1 – 16 (House Code X+11)

(161 - 191)

ALC addresses 1-31, Module 2 - Branch 2 *

193 - 208

HLC Room 25 and 26, UPB Unit ID 193-208, or X-10 modules 1 – 16 (House Code X+12)

209 - 224

HLC Room 27 and 28, UPB Unit ID 209-224, or X-10 modules 1 – 16 (House Code X+13)

(191 - 223)

ALC addresses 1-31, Module 2 - Branch 3 *

225 - 240

HLC Room 29 and 30, UPB Unit ID 225-240, or X-10 modules 1 – 16 (House Code X+14)

241 - 256

HLC Room 31, UPB Unit ID 241-250, or X-10 modules 1 – 16 (House Code X+15)

(225 - 255)

ALC addresses 1-31, Module 2 - Branch 3 *

257 – 272

Outputs 1-16, 1st Expansion Enclosure *

273 – 288

Outputs 1-16, 2nd Expansion Enclosure *

289 – 304

Outputs 1-16, 3rd Expansion Enclosure *

305 – 320

Outputs 1-16, 4th Expansion Enclosure *

321 - 336

Outputs 1-16, 5th Expansion Enclosure *

337 – 352

Outputs 1-16, 6th Expansion Enclosure *

353 - 368

Outputs 1-16, 7th Expansion Enclosure *

369 - 384

Outputs 1-16, 8th Expansion Enclosure *

385 - 392

Voltage Outputs (1-8), Fully Configurable

393 – 511

Internal Flags

“X” Represents the House Code setting on the OmniPro II Controller

“*”

Internal

Flags