Zone event buttons, All on/off event buttons, Upb link event buttons – Home Automation OmniPro II User Manual

Page 71

Advertising
background image

AREA:

ENTER AREA 0=ALL


The area number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas.

WHEN C1 A1 AWAY:

1=DELAY

2=CODE

3=AREA


Zone Event Buttons

Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event. You are first prompted to enter the
desired zone number:

ZONE:

ENTER ZONE


The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones. The
desired zone is then displayed and you are prompted to specify the state that activates the event button:

WHEN Front Door:

0=SECURE 1=NOT RDY


All On/Off Event Buttons

Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a
Leviton Scene command, or issuing a UPB Link command. You are first prompted to specify whether the event button is for All
Lights On, All Off, Leviton Scene, or UPB Link:

ALL

0=OFF

1=ON

2=SCN

3=LINK


If area arming is being used, you will be prompted to specify the desired area:

AREA:

ENTER AREA 0=ALL


If Leviton Scene is selected, you must first specify the scene number:

ENTER SCENE:

1-256

Then select the specified command Off, On, or Set.

If UPB Link is selected, you must first specify the link number:

ENTER

LINK:

1-250


Then select the specified command Off, On, or Set.

UPB Link Event Buttons

When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link
Goto” (as long as the result of the Goto command is not “0”), or “Link Fade Start” (as long as the result to the Fade command is
not “0”) message is received.

When a program is created that uses “When Link Off” as the trigger, the program will execute when a “Link Deactivate” or “Link
Goto” (where the result of the Goto command is “0”) message is received.

Using HAI PC Access Software, you can create a program that uses “When Link Fade Stop” as the trigger. When this trigger is
used, the program will execute when the “Link Fade Stop” message is received.

Page 63

Advertising