Installation, Aquastat installation – Harman Stove Company SF160 User Manual

Page 6

Advertising
background image



Bolt the Automatic Draft Control through

the 1/2 in. hole in the center of the bottom door.

Be sure to hold the Draft Control straight while

tightening. Feed the two wires from the draft mo-

tor through the flexible conduit and a 90˚ fitting.

Secure the fitting to the draft motor and that end

of the conduit at this time. Check the flapper door

on the Automatic Draft Control assuring that it

moves freely.

Install the (3) brass coil spring handles

onto the door latches and the shaker handle. Start

the spring handle onto the shaft and twist it coun-

ter-clockwise while pushing.

Aquastat Installation

(See optional items, page 7)

Lay the din rail

on a flat surface, with the flat side down. Secure

one end clamp, on the left side. Slide the A350

controller onto the rail from right to left until it is

against the end clamp. Slide the Y350 onto the

rail and guide the plug-in connector, joining it to

the A350. Next, install the S350, again, guiding

the plug-in connector carefully. Install the other

end clamp to the right side of the din rail. Remove

the covers from all three controls by loosening

four screws each. Install the terminal box to the

controls using (3) chase nipples and locknuts,

supplied with the kit. Using the four holes in the

terminal box, mount the terminal box and controls

to the boiler sheet metal side as shown in Fig.1.

Using (2) #8-32 nuts, install the terminal block

onto the studs located inside the terminal box.

Wiring Diagram

Installation

FIG.

Advertising