R

3100 Wood Stove Series (ACC)

B. Outside Air Kit Installation

1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the flex adapter

to the stove using 4 screws.

Figure 14.1

. Remove circular” knock-out” in the base of the pedestal.
4.

Floor & Rear Installation: Cut a 4 inch (102mm)

hole in outside wall or floor to accommodate outside

air piping. Use 4 inch (102mm) aluminum metal flex or

rigid piping to directly connect outside air to appliance

intake. Use the supplied termination cap with a rodent

screen. Seal between the wall (or floor) and the pipe

with silicone to prevent moisture penetration.

Items Needed for Installation (not supplied)

• 4 inch flex aluminum pipe, or if using alternate material,

then it shall be made from durable, non-combustible,

heat resistant material up to 50

o

F. Cut the pipe to

the required length for your installation.

• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through

the wall or flooring in your home.

Figure 14.1 - Floor & Rear Installation

A source of air (oxygen) is necessary in order for combus-

tion to take place. Whatever combustion air is consumed

by the fire must be replaced. Air is replaced via air leak-

age around windows and under doors. In homes that have

tightly sealed doors and windows, an outside air source is

needed. An optional Outside Air Kit is available.

Flex Line

Wire Tie

Wire Tie

Flex Adapter

Termination

Cap

Remove circular

“knock-out” in base

of pedestal.

WARNING

Do not draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or

chimneys

Fumes or odor may result

Fire Risk.
Asphyxiation Risk.

Asphyxiation Risk.
Outside air inlet must be located to prevent block-

age from:
• Leaves
• Snow or ice
• Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensi-

tive individuals.

WARNING

Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed

the length of the vertical height of the exhaust flue.
Fire will not burn properly
Smoke spillage occurs when door is opened due

to air starvation.

WARNING

Included in OAK-ACC:

Termination cap, (2) wire ties, flex

adapter, and fasteners

Included in SRV7033-041:

Cover plate and sealing rope (see

Floor Installation Alternative below,

Figure 14.2)

Figure 14.2 - Floor Installation Alternative

Cover

Plate

Rope to Seal

Pedestal

5.

Floor Installation Alternative: In some instances you

may not be able to install the flex pipe as show in

Figure

14.1. If that is the case, you will need to order SRV70-

041 which includes a cover plate and sealing rope as

shown in

Figure 14.2. The goal is to seal the pedestal

so no room air can leak into the pedestal.