Installation – Heath Zenith HEATH CB-2011 User Manual

Page 2

Advertising
background image

598-1111-01

2

INSTALLATION

For easy installation, select an existing light with a wall
switch for replacement.

W

IRE

THE

L

IGHT

C

ONTROL

.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two
screws that fit your junction box.

The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.

Route the Light Control’s wires through the large
gasket hole.

M

OUNT

THE

L

IGHT

C

ONTROL

.

Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the
wall plate mounting surface with silicone weather
sealant.

For eave mount only:

Swing the sensor head towards the clamp screw
joint.

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint.

Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180

°

so

the controls face down.

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

1234567890123456789

1234567890123456789

1234567890123456789

Controls

Clamp Screw

Controls

Controls

Lock Nut

To avoid water damage and elec-
trical shock, keep lamp holders
below horizontal.

Keep lamps at least
1" (2.5 cm) from the
sensor.

Do not allow

the lamps to block
the lens.

Lens

Twist the junction box wires and fixture wires

together

as shown. Secure with wire connectors.

White to
White

Black to
Black

Junction box ground wire to
green ground screw on fixture.

Gasket

Mounting

Strap

Mounting

Bolt

Rubber

Plug

CAUTION: To avoid fire or burn hazards, keep
fixture at least 2" (51mm) from combustible mate-
rials. Do not aim at objects closer than 3' (1m).

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180

°

from the factory setting. When screwing in the
floodlamps, do not overtighten.

Advertising