TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 1

1

/

2

minute warm up period

before it will detect motion.

When first turned

on or when switching modes wait 1

1

/

2

minutes.

Bottom of Sensor

Avoid aiming the sensor at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other
lights at the sensor.

Maximum Range

Maximum

Coverage Angle

8 ft.

(2.4 m)

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.

Adjust the RANGE as
needed.

RANGE set too high

may increase false
triggering.

Secure the sensor head's
aim by tightening the
clamp screw.
Do not over-
tighten the screw.

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . Up to 240

°

Electrical Load . . . . . . Up to 300 Watts Maximum In-

candescent [Up to 150 Watts
Maximum each lamp holder].

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 20 minutes

DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at
any time without incurring any obligation to incorporate
new features in products previously sold.

240

°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME

TEST 1 5 2 0

MINUTES

Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.