ADJUSTING DOOR SAG

To adjust door sag (saw-tooth effect from door to
door), loosen the two hinge plate mounting
screws using a Torx Plus no. 27 bit. Adjust hinge
plate as needed, then tighten the screws. See
Figure 2.

CONDITIONING GASKETS

The manufacturer cannot control the environment
surrounding cases during shipment. Temperature
and humidity fluctuations during shipment, as
well as excessive vibration, may promote gaps
between gasket and frame. These gaps prevent
gaskets from sealing even when correctly fitted at
the factory. This is not a warranty issue or defect.

Follow this procedure to ensure gaps close and
gaskets seal properly:

1. Remove all shipping retainers and packing
material.

2. Close each door. Use a flashlight to identify
any gaps between frame and gasket.

3. Energize all anti-sweat, fan and light circuits
for at least two hours, but not more than four
hours, prior to initiating the refrigeration cycle.

4. Monitor all gaps. If gaps remain at the end of
four hours, follow the procedure for Restoring
Gasket Seal
, beginning on page 6 of this manual.

5. Initiate cooling sequence once gaps disappear.

Do not exceed 8 hours of energized circuits
without refrigeration. Doing so may cause
damage to the case and will void the warranty.

P/N 0425683F

®

2

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Figure 2. Adjusting Door Sag

Loosen both
hinge plate
mounting
screws.

ATTENTION

TO ENSURE PROPER DOOR GASKET SEAL – REMOVE ALL SHIPPING
RETAINERS AND ENERGIZE ALL ANTI-SWEAT, FAN & LIGHT CIRCUITS 2
TO 4 HOURS PRIOR TO INITITATING REFRIGERATION CYCLE.

DO NOT EXCEED 8 HOURS OF ENERGIZED CIRCUITS WITHOUT
REFRIGERATION. DAMAGE OR PRODUCT FAILURE MAY OCCUR AND VOID
THE WARRANTY. DO NOT REMOVE THIS LABEL UNTIL REFRIGERATION IS
INITIATED.