– 30 –

Paging Feature

About Automatic Paging

Your system may be set up to automatically send messages to several pagers (4 pagers
for VISTA-20P Series, 2 pagers for VISTA-15P Series) as certain conditions occur in
your system.
• The following events can be programmed by your installer to be sent to the pagers:

arming and disarming

, alarms, and trouble conditions. (

reports when

arming/disarming from a keypad using a security code; auto-arming/disarming,
arming with assigned button, and keyswitch arming do not send pager messages.)

• You can also program the system to send an automatic pager message to alert you

in the event that someone has not arrived home (disarmed the system) within a
defined period of time (see the Scheduling section for details on programming a
“latch key report”).

• Your installer programs the pager phone numbers and reporting events.

• The pager message consists of a 7-digit system status code that indicates the type of

condition that has occurred.

• An optional, predefined 16-digit character string can precede the 7-digit system

status code; these characters can consist of a PIN no., subscriber account no., or any
additional data that you may wish to have sent to the pager.

• The pager display format is as follows:

Optional 16 digits

3-digit Event Code

И

И

И

И

И

И

И

И

AAAAAAAAAAAAAAAABBBCCCC

Е

Е

Е

Е 1-digit Partition No. + 3-digit Zone No. or User No.

A =

B =

C =

Optional 16-digits for
Account numbers,
PIN numbers, or any
other data;
programmed by the
installer, if required.

A 3-digit code that

describes the event
that has occurred
in your system
(see for event
codes table below)

A 1-digit Partition number plus a 3-digit Zone or User
number, depending on the type of event that has
occurred, where:
• alarms and troubles display zone number

• arming/disarming (opens/closes) display user number

The 3-digit Event Codes (BBB) that can be displayed are:

911 =

811 =

101 =

102 =

Alarms.

The 4-digit number
(CCCC) following this
code is the partition no.
and zone no. that
caused the alarm.

Troubles.

The 4-digit number
(CCCC) following this
code is the partition no.
and zone no. that
caused the trouble.

Open

(system disarmed).

The 4-digit number
(CCCC) that follows
this code is the
partition no. and user
no.
that disarmed the
system.

Close

(system armed).

The 4-digit number
(CCCC) that follows
this code is the
partition no. and user
no.
that armed the
system.

Examples of typical 7-digit pager displays follow.

Ex. 1. 911 –10 04 = R eporting of an alarm (911) caused by a fault on zone 4 on Partition 1 (1004).

Ex. 2. 102 –20 05 = Reporting of a closing–system arming (102)– by user 5 in Partition 2 (2005).