– 38 –

Scheduling

(cont’d

)

5. For event number “02,” enter the access group

number. Otherwise, this prompt is skipped.

Press

[

∗] to continue to the “Start” prompt below.

GROUP NUMBER

X

6. For event numbers “03-07,” enter the partition

number to be armed or disarmed.

0 = arm all; 1 = partition 1; 2 = partition 2;

3 = arm common

Otherwise, this prompt is skipped.

Press

[

∗] to continue to the “Start” prompt.

PARTITION

X

7. Enter the event’s start time and days of week.

Hour = 00-12; minute = 00-59

AM = 0; PM = 1

Days = Position the cursor under the desired days
using the [

∗] key to move forward, then press “1” to

select the day.

Press

[

∗] to continue.

START SMTWTFS

HH:MMAM 1000000

8. If applicable, enter the event’s stop time and days of

week (applies only to event numbers 01, 02, and 03).

Refer to step 7 for available entries.

Press

[

∗] to continue.

STOP SMTWTFS

HH:MMAM 1000000

9. Enter the desired repeat option.

0 = no repeat

1 = repeat schedule weekly

2 = repeat schedule biweekly (every other week)

3 = repeat schedule every third week

4 = repeat schedule every fourth week

e.g., To make a schedule that happens everyday you
would select all days with a repeat count of 1. To
make a schedule that runs for one week then stops,
select everyday with a repeat count of 0.

REPEAT OPTION
0-4 X

10. For event number 01 (output on/off), select the

randomize option, if desired.

0 = no; 1 = yes

If selected, the schedule times will vary within 60
minutes of the “hour” time. For example, if a
schedule is set to start at 6:15pm, it will do so the
first time 6:15pm arrives, but on subsequent days it
will start anytime between 6:00 and 6:59 p.m.

Press

[

∗] to continue.

RANDOMIZE
0=NO 1=YES

X