Displacement Pump

311797F

17

Displacement Pump

GH130 Only

(Figures 7-12)

See manual 311845 for pump repair instructions

Removal

1. Flush pump.
2. Relieve pressure, page 7.

3. (Fig. 7) Remove suction tube (114) and paint hose (63)

(remove at swivel end).

F

IG

. 7

4. (Fig. 8) Push retaining ring (120) up; push out pin (92).

F

IG

. 8

5. (Fig. 9). Loosen jam nut (86). Unscrew pump (111).

F

IG

. 9

Installation

1. (Fig 10) Screw jam nut (86) to bottom of pump (111)

threads. Screw pump (111) completely into manifold.
Unscrew pump (111) from manifold until pump outlet
aligns with hose. Hand tighten jam nut (86), then tap 1/8
to 1/4 turn with hammer or torque to 75 ft-lb (101 N·m).

F

IG

. 10

2. (Fig. 11) Slowly pull engine starter rope until pump rod pin

hole is aligned with hydraulic rod hole. Fig. 8. Push pin (92)
into hole. Push retaining ring (120) into groove.

F

IG

. 11

3. (Fig. 12) Fill packing nut with Graco TSL.

F

IG

. 12

ti2272a

114

63

TIB

92

120

ti2272c

86

If pin (92) works loose, parts could break off and project
through the air, resulting in serious injury or property dam-
age. Make sure pin is properly installed.

CAUTION

If the pump jam nut (86) loosens during operation, the
threads of the bearing housing and drive train will be dam-
aged. Tighten jam nut (86) as specified.

ti2272d

86

111

TIE

120

92