General Repair Information

6

311797F

General Repair Information

1. Keep all screws, nuts, washers, gaskets, and electrical

fittings removed during repair procedures. These parts
are not normally provided with replacement assemblies.

2. Test repair after problem is corrected.
3. If sprayer does not operate properly, review repair

procedure to verify procedure was done correctly. If
necessary, see Troubleshooting Guide, page 7, for other
possible solutions.

4. Install belt guard before operation of sprayer and replace if

damaged. Belt guard reduces risk of pinching and loss of
fingers; see preceding WARNING.

Grounding

Ground sprayer with grounding clamp to earth ground
for safe sprayer operation when using solvent-based
materials. Fig. 1.

F

IG

. 1

SAE O-Ring Installation

1. Unscrew lock nut to touch fitting.

2. Lubricate o-ring (A).

3. Screw in fitting hand tight.

4. Unscrew fitting until oriented

properly.

5. Tighten lock nut to indicated torque.

(Make sure washer is seated properly
without pinching o-ring).

To reduce risk of serious injury, do not touch moving
parts with fingers or tools while testing repair. Shut
off sprayer when repairing. Install all covers, gaskets,
screws and washers before operating sprayer

6250

A

ti5414a

ti5415a

ti5416a

ti5417a