Notice:

This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations,
CRC c. 1374.

1

4

COMPRESSOR

CONTACTOR

HEAT

CHANGEOVER

VALVE

COOL

CHANGEOVER

VALVE

FAN

RELAY

M19453

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS

AND OVERLOAD PROTECTION AS REQUIRED.

2 FACTORY INSTALLED JUMPER.

3 USE A JUMPER WIRE (NOT SUPPLIED) TO CONNECT W TO Y.

4 USE EITHER O OR B FOR HEAT PUMP CHANGEOVER.

3

2

W

R

Rc

B

O

Y

G

1

2

1

HEATING

RELAY OR

VALVE COIL

COMPRESSOR

CONTACTOR

FAN

RELAY

M19454

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS

AND OVERLOAD PROTECTION AS REQUIRED.

REMOVE FACTORY INSTALLED JUMPER BETWEEN R AND RC.

W

R

Rc

B

O

Y

G