Honeywell CT8775A User Manual

Page 9

Advertising
background image

9

69-1676—1

Table 2. Terminal Designations on Old and New Thermostats.

NOTES:

1.

If wires were connected to both Rh and R terminals on the old thermostat, remove jumper between R and Rc on
the new thermostat and connect Rh to R and R to Rc.

2.

If wires will be connected to both R and Rc on the new thermostat, remove jumper between R and Rc.

3.

Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B with electri-
cal tape and do not use.

4.

Tape off wire with electrical tape and do not use.

Terminal on

Old

Thermostat

Connect to Terminals

on CT8775A

Connect To Terminals

on CT8775C

Description

R
Rh

(see Note 1)

4
V

R

R

(see Note 2)

Power

Rc
R

(see Note 1)

Rc

(see Note 2)

Power for cooling

W, W

1

, H

W

W

Heat

Y, Y

1

, M

Y

Cooling

G, F

G

Fan

O

O

Changeover in cool. (Single stage heat pump
only).

B

(see Note 3)

B

(see Note 3)

Changeover in heat. (Single stage heat pump
only).

C

(see Note 4)

X

(see Note 4)

B

(see Note 3)

Do not connect.

Do not connect.

Transformer common

W

2

, H

2

Do not continue
installation. Call 1-800-
468-1502.

Do not continue
installation. Call 1-800-
468-1502.

Second stage heat.

Y

2

Second stage cool.