Maintenance – Homelite UT80993 User Manual

Page 17

Advertising
background image

Page 13 — English

MAINTENANCE

Spark Plug:

Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle
oil through the spark plug hole into the combustion
chamber.

Leaving the spark plug out, pull the starter cord two or
three times to coat the inside of the cylinder wall.

Inspect the spark plug and clean or replace, as necessary.

Reinstall the spark plug, but leave the spark plug wire
disconnected.

Air Filter:
Clean the air filter.
Hoses and Pump:
Flush the injection hose with clean water for 1-2 minutes.
Remove all hoses. Empty the pump by pulling on the recoil
starter about 6 times. This should remove most of the liquid
from the pump.

WARNING:

Ensure all engine covers and all engine parts are com-
pletely and properly reassembled before starting engine.
Failure to correctly reassemble engine may result in seri-
ous injury or property damage.

PREPARING FOR USE AFTER STORAGE

Pull the recoil starter grip three or four times to clean oil
from the combustion chamber.

Remove spark plug from the cylinder. Wipe oil from the
spark plug and return it to the cylinder.

Reconnect the spark plug wire.

Refuel the machine as described earlier in the operator’s
manual.

NOZZLE MAINTENANCE

Excessive pump pressure (a pulsing sensation felt while
squeezing the trigger) may be the result of a clogged or
dirty nozzle.

Turn off the pressure washer and shut off the water
supply. Pull trigger to release water pressure.

Remove the nozzle from the spray wand.

NOTE: Never point the spray wand at your face.

Using a straightened paper clip or nozzle cleaning tool
(not provided), free any foreign materials clogging or
restricting the nozzle.

Using a garden hose, flush debris out of nozzle by back
flushing (running the water through the nozzle backwards
or from the outside to the inside).

Reconnect the nozzle to the spray wand.

Turn on the water supply and start the engine.

LONG-TERM STORAGE OF THE PRESSURE
WASHER

See Figure 17.
Store the pressure washer with the gas tank empty by either
draining the tank or running the pressure washer until the
gas runs out. Allow 30 minutes of “cool down” time before
storing the machine. Store in a dry, covered area where the
weather can’t damage it.
It is important to store this product in a frost-free area. Always
empty water from all hoses and the pump.
NOTE: Use of a fuel stabilizer and pump saver will give you
better performance and increase the life of the machine.
Discharge Fuel:
Drain the fuel tank completely. Stored gas can go stale in
30 days.
Engine Oil:
Drain the oil and replace with fresh, clean oil.

Advertising