RTH6400

27 69-2416ES—05

Troubleshooting

SETUP

WIRING

ASSIST

ANCE

TROUBLESHOOTING

Heating or
cooling system
does not
respond

• Press

SYSTEM button to set system

to Heat. Make sure the temperature
is set higher than the Inside
temperature.

• Press

SYSTEM button to set system

to Cool. Make sure the temperature
is set lower than the Inside
temperature.

• Check circuit breaker and reset if

necessary.

• Make sure power switch at heating

& cooling system is on.

• Make sure furnace door is closed

securely.

• Wait 5 minutes for the system to

respond.

“Cool On” or
“Heat On” is
flashing

• Compressor protection feature is

engaged. Wait 5 minutes for the
system to restart safely, without
damage to the compressor.

Heat pump
issues cool air
in heat mode,
or warm air in
cool mode

• Check Function 2: Heat Pump

Changeover Valve to make sure

it is properly configured for your

system (see page 15).

Heating system
is running in
cool mode

• Check Function 1: System Type to

make sure it is set to match your

heating and cooling equipment

(see page 14).

Advertising