Planning and Design

2–11

Hitachi Simple Modular Storage Copy-on-Write SnapShot User’s Guide

b. Right-click the disk whose HLUN you want to know, then select

Properties. The number displayed to the right of “LUN” in the dialog

window is the HLUN.

2. Identify HLUN-to-LUN Mapping.

a. In Start Storage Navigator Modular 2, select the desired array.
b. In the array tree that displays, click the Group icon then click iSCSI

Target icon in the Groups tree.

c. On the iSCSI Target screen, select an iSCSI target.
d. On the target screen, select the Logical Units tab. Find the identified

HLUN. The LUN displays in the next column.

e. If the HLUN is not present on a target screen, on the iSCSI Target

screen, select another iSCSI target and repeat Step

d

.

Cluster Software, Path Switching Software

Do not make the V-VOL an object of the cluster software and the path

switching software.

Microsoft Cluster Server (MSCS)

A host cannot recognize both a P-VOL and its V-VOL at the same time. Map

the P-VOL and V-VOL to separate hosts.

Veritas Volume Manager (VxVM)

A host cannot recognize both a P-VOL and its V-VOL at the same time. Map

the P-VOL and V-VOL to separate hosts.

Windows 2000

Multiple V-VOLs per P-VOL cannot be recognized from the same host. Limit

host recognition to one V-VOL.

Windows Server 2003

• Multiple V-VOLs per P-VOL cannot be recognized from the same host.

Limit host recognition to one V-VOL.

• When mounting volumes, must use the CCI mount command. Do not

use mountvol command that is included in Windows Server 2003 by

standard. Please install CCI on the server on which the mount command

is to be executed. For more information, see the Hitachi Simple Modular

Storage Command Control Interface (CCI) Reference Guide.

• When using CCI, if a path fails for more than one minute, the command

device may not be recognized when the path is recovered. Execute

Windows’ “re-scan the disks” to make recovery. Restart CCI if Windows

cannot access the command device even if CCI is able to recognize it.