RCT8100 Programmable Thermostat

11

1)

Press both and buttons simultaneously for 3
seconds to enter or exit the setup menu.

2)

To advance to the next function, briefly press both

and buttons simultaneously.

3)

To change the setting, press the or button.

w

System Setup

9.

DISPLAY

DESCRIPTION

OPTIONS

1

Temperature display

°C or °F

Time display

12 h or 24 h

Early Start

2

On or Off

Heating cycles per hour

3

2, 3, 4, 5 or 6

4

Cooling cycles per hour

3

2, 3, 4, 5 or 6

5

1

Default settings are shown in bold and underlined.

2

See page 3 of Operating Manual.

3

Use the system switch to switch between the two parameters.

4

For optimal heating control, use the setting that matches your sys-

tem as follows: 2=30 min (steam, gravity), 3=20 min (hot water,
90%+ high-efficiency furnace), 4=15 min (gas or oil), 5=12 min
(alternate setting for gas or oil), 6=10 min (electric).

5

The corresponding cooling cycle lengths are as follows: 2=30 min,

3=20 min, 4=15 min, 5=12 min, 6=10 min