E. Valve Access

Figure 6.1

Loosen Refractory Retaining Strip

Figure 6.2

Lift Out Doors

Figure 6.3

Remove Valve Access Panel

Figure 6.4

Remove Exterior Valve Access Panel

Figure 6.5

Connect Manometer

• The gas valve can be accessed behind the cement

refractory panel on the right side of the fi replace. Use a
phillips screwdriver to remove the two screws securing
the refractory retaining strip.

• Lift doors out and set aside. Remove the refractory side

panel and set aside.

• Remove the inside valve access panel by lifting it up and

out.

• Use a phillips screwdriver to remove the exterior valve

access panel.

• Use a manometer on the lower out pressure tap. Start

up the fi replace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.