Caution, Warning, Electrical information – Hearth and Home Technologies Heat-N-Glo Dakota 42 User Manual

Page 13: A. recommendation for wire, C. intellifi re ignition system wiring, B. connecting to the appliance

Advertising
background image

Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05

13

Battery polarity must be correct or module damage will
occur.

CAUTION

Note: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition
or the Canadian Electric Code,
CSA C22.1.

A. Recommendation for Wire

Shock Risk
Explosion Risk

Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
• Incorrect wiring will damage millivolt

values.

• Incorrect wiring will override IPI safety

lockout and may cause explosion.

WARNING

• This appliance may be used with a wall switch.

Use low resistance thermostat wire for wiring from ignition
system to the wall switch.

• Keep wire lengths short as possible by removing any

excess wire length, not to exceed 18 ft.

Low voltage and 110 VAC voltage cannot be shared within
the same wall box.

C. Intellifi re Ignition System Wiring

This appliance requires two “D” size batteries (3V) supply
to the appliance valve for operation. A wiring diagram is
shown in Figure 7.1.

• This appliance is equipped with an Intellifi re control valve

which operates on a 3 volt system.

• This appliance is supplied with a battery pack which is

located inth e ON/OFF switch terminal box.

• The battery pack requires two D cell batteries (not

included).

7

Electrical Information

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

Shock Risk

Replace damaged wire with type 105° C
rated wire.

• Wire must have high temperature

insulation.

CAUTION

B. Connecting to the Appliance

IGNITION MODULE

3 VAC

GRN

ORG

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

BATTERY

PACK

FLAME SPARKER/

SENSOR

SEE NOTE 1

ORG

WHT

PIGGYBACK

ON/OFF SWITCH

BRN

BRN

VALVE

VALVE

GROUND TO
FIREPLACE
CHASSIS

I

S

BLACK

RED

BATTERY

PACK

Figure 7.1

Intellefi re Pilot Ignition (IPI) Wiring Diagram

Advertising