Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05

Fire Risk

Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.

Modifying or covering grilles could cause
temperature rise and fi re hazard.

Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
• Operation of louvers or doors.
• Access for service.

WARNING

A. Mantel Projections

Figure 8.1 shows the minimum vertical dimension of appli-
ance mantels or other combustible projections above the top
front edge of the appliance.

B. Facing Material

Free Standing Installation

COMBUSTIBLE

STRUCTURE

Minimum
Clearance *

* This appliance can be installed a minimum of 6 in.
(152 mm) from a combustible structure unless the
structure is vinyl which requires a minimum
clearance of 48 in. (1219 mm)

84 in.

(2134 mm)

min.

Figure 11.1 Clearances to Mantels or other Combustibles above Appli-

ance.

Figure 11.2 Noncombustible Facing Diagram

8

Finishing

Fire Risk

Finish all edges and fronts to clearances and
specifi cations listed in manual.

WARNING

Black metal appliance front may be covered with non-
combustible material only.

Do NOT overlap combustible materials onto appliance
front.

Install combustible materials up to specifi ed clearances
on top front and side edges.

• Seal joints between the fi nished wall and appliance

top and sides using only a 300° F minimum sealant.

Sealant Material

Noncombustible Board

Finish wall material may be combustible, top and sides

0 in.

0 in.

0 in.