Hubbell Electric Heater Company HSE User Manual

Page 15

Advertising
background image

15

HEATING ELEMENT

1. Disconnect power from unit.
2. Shut off incoming water supply.
3. Attach hose to drain connection.
4. Lift manual release lever on relief valve to let air into system or break union on outgoing

water line.

5. Drain water from tank.
6. Disconnect the wires from the heating element terminals.
7. Remove the 3/8-16 nuts.

Tank Flange

Element Terminals

Nuts

8. Withdraw element assembly and remove gasket.

Gasket

Element Assembly

9. Install new gasket and insert new heating element.
10. For 3-phase heaters, rewire the element according to the voltage and phase rating of the unit

as shown below. For single phase operations, connect wires to terminals.

11. Fill tank and check around gasket for any leaks.

Advertising
This manual is related to the following products:

HE