PIPING INSTALLATION

NOTE: The most effective means for preventing deterioration from accelerated corrosion due to
galvanic and stray current is the installation of dielectric fittings/unions. The installation of these
fittings is the responsibility of the installing contractor.

1. Thread cold water inlet and diffuser assembly into tank. Diffuser slots must be pointing down

toward the bottom of the tank.

Cold Water Inlet Diffuser




Diffuser Slots

Drain Valve

2. Connect the cold water inlet and hot water outlet to the appropriate connections as shown;

refer to the drawing for location and sizes.

3. Install in-line vacuum breaker, if supplied.

4. Install in-line pressure and temperature gauge, if supplied.

5. Install the combination temperature and pressure safety relief valve in the tapping provided.

Note that this is required by law for safety considerations.


Outlet to floor drain Install into provided tapping

Manual Release

Lever

Temperature Probe

6. Install a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of any type

should be installed between the relief valve and tank or in the drain line.